BibTex RIS Cite

Intraocular pressure menagement with transpalpebral tonometry

Year 2013, Volume: 35 Issue: 4, 615 - 617, 30.12.2013

Abstract

Applanation tonometry is the method of measuring intraocular pressure (IOP) with instruments the corneal surface. The Goldmann applanation tonometer (GAT) is regarded as the “gold standard’’ of measuring IOP. An irregular and opaque corneal surface compromises IOP measurement by Goldmann applanation tonometry. In such cases accurate measurement without corneal contact would be applicable. The transpalpebral tonometer is new method and measures IOP without corneal contact through the eyelid.

References

  • The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration.The AGIS Investigators. Am J Ophthalmol 2000; 130: 429-40.
  • Doherty MD, Carrim ZI, O’Neill DP. Diaton tonometry: an assessment of validity and preference against Goldmann tonometry. Clin Experiment Ophthalmol 2012; 40: e171-5.
  • Toker MI, Vural A, Erdogan H, Topalkara A, Arici MK. Central corneal thickness and Diaton transpalpebral tonometry. Graefes Arch Clin Exp Ophthalmol 2008; 246: 881-9.
  • Sandner D, Böhm A, Kostov S, Pillunat L. Measurement of the intraocular pressure with the “transpalpebral tonometer” TGDc-01 in comparison with applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2005; 243: 563-9. Troost A, Yun SH, Specht K, Krummenauer F, Schwenn O. Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers. Br J Ophthalmol 2005; 89: 280-3.
  • Li Y, Shi J, Duan X, Fan F. Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2010; 248: 1765-70.
  • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000; 44: 367-408.

Transpalpebral tonometri ile göz içi basıncı ölçülmesi

Year 2013, Volume: 35 Issue: 4, 615 - 617, 30.12.2013

Abstract

Applanasyon tonometrisi kornea yüzeyinden aletler kullanılarak göz içi basıncı ölçen bir yöntemdir. Goldman applanasyon tonometrisi göz içi basınç ölçümünde altın standart olarak görülmektedir. Düzensiz ve opak kornealarda Goldman applanasyon tonometrisi ile göz içi basınç ölçümü güçleşmektedir. Bu gibi durumlarda korneaya temas olmadan ölçüm yapmak daha uygun olacaktır. Transpalpebral tonometri korneal temas olmadan göz kapağı üzerinden göz içi basıncı ölçen yeni bir metoddur.

References

  • The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration.The AGIS Investigators. Am J Ophthalmol 2000; 130: 429-40.
  • Doherty MD, Carrim ZI, O’Neill DP. Diaton tonometry: an assessment of validity and preference against Goldmann tonometry. Clin Experiment Ophthalmol 2012; 40: e171-5.
  • Toker MI, Vural A, Erdogan H, Topalkara A, Arici MK. Central corneal thickness and Diaton transpalpebral tonometry. Graefes Arch Clin Exp Ophthalmol 2008; 246: 881-9.
  • Sandner D, Böhm A, Kostov S, Pillunat L. Measurement of the intraocular pressure with the “transpalpebral tonometer” TGDc-01 in comparison with applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2005; 243: 563-9. Troost A, Yun SH, Specht K, Krummenauer F, Schwenn O. Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers. Br J Ophthalmol 2005; 89: 280-3.
  • Li Y, Shi J, Duan X, Fan F. Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2010; 248: 1765-70.
  • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000; 44: 367-408.
There are 6 citations in total.

Details

Primary Language English
Journal Section Reviews
Authors

Mustafa Toker

Ayhan Dursun

Publication Date December 30, 2013
Published in Issue Year 2013Volume: 35 Issue: 4

Cite

AMA Toker M, Dursun A. Intraocular pressure menagement with transpalpebral tonometry. CMJ. December 2013;35(4):615-617.