Intraocular pressure menagement with transpalpebral tonometry
Öz
Applanation tonometry is the method of measuring intraocular pressure (IOP) with instruments the corneal surface. The Goldmann applanation tonometer (GAT) is regarded as the “gold standard’’ of measuring IOP. An irregular and opaque corneal surface compromises IOP measurement by Goldmann applanation tonometry. In such cases accurate measurement without corneal contact would be applicable. The transpalpebral tonometer is new method and measures IOP without corneal contact through the eyelid.
Anahtar Kelimeler
Kaynakça
- The Advanced Glaucoma Intervention Study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration.The AGIS Investigators. Am J Ophthalmol 2000; 130: 429-40.
- Doherty MD, Carrim ZI, O’Neill DP. Diaton tonometry: an assessment of validity and preference against Goldmann tonometry. Clin Experiment Ophthalmol 2012; 40: e171-5.
- Toker MI, Vural A, Erdogan H, Topalkara A, Arici MK. Central corneal thickness and Diaton transpalpebral tonometry. Graefes Arch Clin Exp Ophthalmol 2008; 246: 881-9.
- Sandner D, Böhm A, Kostov S, Pillunat L. Measurement of the intraocular pressure with the “transpalpebral tonometer” TGDc-01 in comparison with applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2005; 243: 563-9. Troost A, Yun SH, Specht K, Krummenauer F, Schwenn O. Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers. Br J Ophthalmol 2005; 89: 280-3.
- Li Y, Shi J, Duan X, Fan F. Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry. Graefes Arch Clin Exp Ophthalmol 2010; 248: 1765-70.
- Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 2000; 44: 367-408.
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
-
Yayımlanma Tarihi
30 Aralık 2013
Gönderilme Tarihi
2 Ağustos 2012
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2013 Cilt: 35 Sayı: 4
APA
Toker, M., & Dursun, A. (2013). Intraocular pressure menagement with transpalpebral tonometry. Cumhuriyet Medical Journal, 35(4), 615-617. https://izlik.org/JA68JW75JA
AMA
1.Toker M, Dursun A. Intraocular pressure menagement with transpalpebral tonometry. CMJ. 2013;35(4):615-617. https://izlik.org/JA68JW75JA
Chicago
Toker, Mustafa, ve Ayhan Dursun. 2013. “Intraocular pressure menagement with transpalpebral tonometry”. Cumhuriyet Medical Journal 35 (4): 615-17. https://izlik.org/JA68JW75JA.
EndNote
Toker M, Dursun A (01 Aralık 2013) Intraocular pressure menagement with transpalpebral tonometry. Cumhuriyet Medical Journal 35 4 615–617.
IEEE
[1]M. Toker ve A. Dursun, “Intraocular pressure menagement with transpalpebral tonometry”, CMJ, c. 35, sy 4, ss. 615–617, Ara. 2013, [çevrimiçi]. Erişim adresi: https://izlik.org/JA68JW75JA
ISNAD
Toker, Mustafa - Dursun, Ayhan. “Intraocular pressure menagement with transpalpebral tonometry”. Cumhuriyet Medical Journal 35/4 (01 Aralık 2013): 615-617. https://izlik.org/JA68JW75JA.
JAMA
1.Toker M, Dursun A. Intraocular pressure menagement with transpalpebral tonometry. CMJ. 2013;35:615–617.
MLA
Toker, Mustafa, ve Ayhan Dursun. “Intraocular pressure menagement with transpalpebral tonometry”. Cumhuriyet Medical Journal, c. 35, sy 4, Aralık 2013, ss. 615-7, https://izlik.org/JA68JW75JA.
Vancouver
1.Mustafa Toker, Ayhan Dursun. Intraocular pressure menagement with transpalpebral tonometry. CMJ [Internet]. 01 Aralık 2013;35(4):615-7. Erişim adresi: https://izlik.org/JA68JW75JA